每个板块注胶总长度(mm)
Total Injection Length per Panel (mm)
长方体耐候胶尺寸(mm)
Rectangular Weather-proofing Sealant Dimensions (mm)
宽度
Width
厚度
Thickness
每个板块注胶总长度(mm)
Total Injection Length per Panel (mm)
三角型密封胶尺寸(mm)
Triangular Sealant Dimensions (mm)
直角边1
Right-angle Side 1
直角边2
Right-angle Side 2
板块数量(块)
Number of Panels (piece)
用胶总量(ml):
Total Sealant Volume (ml)
用胶总量:
Total Sealant Volume
单组分300ml/支
One-component, 300ml/Tube
单组分500ml/条
One-component, 500ml/Sausage
单组分590ml/条
One-component, 590ml/Sausage
备注:
Note:
半隐框幕墙的耐候胶用量计算:每个板块计算1个隐框边长度和2个明框边长度(2个明框边的三角形胶缝)。
Calculation of weather-proofing sealant usage for semi-hidden frame curtain walls: For each panel, calculate the length of 1 hidden frame side and 2 exposed frame side sides (triangular sealant joints for the 2 exposed frame sides).
注:此用量仅供参考,因缝隙大小、基材厚度不同,打胶的平整度、施工也会有一定的损耗,实际用量会有一定偏差。
Note:This dosage is for reference only. Due to differences in gap size, substrate thickness, smoothness of application, and material loss during the application process, the actual dosage may vary.